Sanitary Heat Exchanger (MHE)



MHE - Laboratory Sample Condenser

The MHE (Miniature Heat Exchanger) Double Tube and Shell heat exchanger have been designed to
allow Clean Steam (CS) and Water for Injection (WFI) samples to be taken quickly and easily whilst
maintaining a sterile testing environment.

MHE - is ideal to be mounted at the sampling point and can be operated with either mains or chilled water
as the cooling medium availability of aseptic/sterile sample valve allow fine control of sample flow during
testing

The MHE can be sterilized in situ-on-line, thus ensuring continuity of samples regardless of testing frequency,
ideal for fluids in pharmaceutical/Biotech or any type of high purity systems applications.





Technical Data

Execution:
Horizontal or vertical, fully self-drainable

Connections:
Tube side: ½” clamp BS 4825
Shell side: ¾” clamp BS 4825

Operating conditions:
Maximum working pressure: 8 barg at 175°C both sides (shell and tube)
Note – pressure rating may exceed that of clamps connections

Capacities (approximate):
Steam: up to 10 kg/h of condensate at 100°C
Water: 30 lt/h of water from 85°C to 30°C
based on a cooling water temperature of 18°C and flow rate of 10 lt/min.

Material
Thermal insulations with rock wool
AISI 304 safety sheet
Support brackets

Finish
Surface finish: internal Ra ≤0.6µ external mirror polished
Optional
Mirror polish, electropolished,
DIN 11851 or SMS connections